The series covers the frequency range of 25 to 2500 MHz. Each model is tunable over an octave bandwidth with notch depths of at least 45 dB.
The units are tuned via a knob with a dial calibrated in MHz and accurate to ±1%. Passband loss is typically less than 0.5 dB and passband VSWR is typically less than 1.2:1. SMA connectors* and 50 Ohm impedance will be considered standard. Units are housed in an aluminum case with high "Q" cavities.
These filters can be used to eliminate undesired signals as close to the passband as 500 kHz for the low band unit and 3 to 8 MHz for the 500 to 1,000 MHz band. For special requirements not covered by these standard models, please contact the factory. These units are ideally suited for precision test & measurement environments.
| 3VNF Series Request a Quote | |
|---|---|
| Frequency Range | 25–50 MHz 50–100 MHz 100–200 MHz 200–400 MHz 250–500 MHz 500–1000 MHz 1000–2000 MHz 1500–2500 MHz |
| Connector | SMA Female |
| Impedance | 50 Ohms |